Pci-7344. freedesktop. Pci-7344

 
freedesktopPci-7344  in another word it will show me the STL file is being created layer by layer

Now their is a connector on the Motion control card for Digital I/O. Due to synchronization constraints I need hardware scanning synchronized with some internal clock instead of software scanning using a set. Because of the reason mentionned in the link in my first mail, I doubt that a calibration certificate exists for this card. I am a Master’s student of International Islamic University Malaysia. It takes 10-20 milliseconds to start the move after the trigger. Because sometimes you need a hard copy. This drive is part of an adjustment mechanism which should remain in a stable. 7350 and 7340. . Hi all, I'm using the output pins of the 7344 - board. The PCI‑7344 also provides contouring capability for complex moves. 1. We facilitated the wiring of inputs to each of these components with NI SCB-68 digital I/O connector block and the UMI-7764 motion interface. 2. It includes dual processors, a real-time. The Stepper Motors on My machine don't move on my machine, I have PCI -7344 card connected to UMI 7764 with 68 pin connector. Send documents to the printer connected to your host computer or to the printer connected to the computer you are. I am already using one. また、NIのホームパージから. Try searching for what you need. Manufacturer: National Instruments. Any help is appreciate. Currently the only terminal block we have is SCB-68, and we will need to use the motion I/O port of the PCI-7344. org Mon Sep 8 22:44:35 PDT 2014. Without seeing the program, it's impossible to tell but execution highlighting and single step mode changes the way the program executes and. 1 asks for firmware upgrade. If you are installing the FW-7344, connect the controller to your computer’s IEEE-1394 port. Giridhar, everything is ok with your 7344. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. Features The 7344 controllers are a combination of servo and stepper motor controllers for PCI, PXI, and 1394 bus computers. Two of the four linear motors drive the parallel tracks in an H-Bridge (X and X') The third linear motor drives the crossbar. Best regards, Jochen Klier. 0. Should I setup my limit switches to stop the axis at the limit and then reset encoders there or what? Or should I have a home switch somewhere in the center of travel and let Labview reset the encoders at. To facilitate learning, we mounted all the motion controlled items, such as three power supplies, two torque amplifiers and oneDescription. Remote Printing. Refer to the Glossary section of this manual for definitions of selected related terms. In our normal system, we use 16 or 12 bit S/. You willI have a E-Stop button on my machine. NI 7350 NI 7352, NI 7354, NI 7356, NI 7358. 2 version but I can't be initialize the motion card in MAX Discontinued NI motion products (PCI/PXI-7334) Affected model numbers include: PCI-7332; PCI-7334; PCI-7342; PCI-7344; PCI-7352; PCI-7354; PCI-7356; PCI-7358 Solved: I install NI PCI-7344. Hi, I use PCI-7344 and UMI-7764 and upgrade the motion software and firmware to 7. This makes the motor really hot. If you are upgrading from a previousHi, How do you reset the encoder count on a servo motor without reseting the position of the motor itself? "Reset encoder count" VI doesn't work. Active Participant. It breaks out the signals available from the PCI-7344. flx) to trigger a move (Start Motion. the PCI-7344 or PCI-7342 board. Seller assumes all responsibility for this listing. I am currently working on a project related to nanomotion stage control using PCI-7344 and LabVIEW 6. Lai Wechat:17750010683 Whats app:+86 17750010683Hello, I am fairly new to LabVIEW and was wondering how to implement incremental rotary encoders into a motion control VI. I have one 3 axes(X,Y,Z) mchine. I have PCI-7344 and PCI-6023E and I want to synchronize them so that my DAQ card will start and stop the acquisition definitely when the motion start and stop. . Previous message: [systemd-commits] src/core Next message: [systemd-commits] 2 commits - Makefile. Installing/reinstalling LV or CVI doesn't necessarily install NI-Motion. "The polarity of the trigger input is programmable in software as active-low (inverting) or active-high (non-inverting), rising or falling edge. . NATIONAL INSTRUMENTS NI-PCI-7344. 0 Kudos Message 1 of 3 (5,141 Views) Reply. I am using Acquire Trajectory Data. 05-10-2006 05:05 PM. . I'm trying to write the program in LabView to respond after the E-stop button is release. PCI-7344 Servo Products from NATIONAL INSTRUMENTS 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, MOTION. The 7340 uses the same configuration and runs the same firmware as the 7344. The "Encoder Index found" led is green. I have verified the connection is working. I am adding a fourth, separate axis of motion to the system. However, simulating the PCI-7344 will allow you to set up a program to work with a 4-axis motion controller and look into. 3003 to 7. This version of "FlexMotion4. item 5 National Instruments NI PCI-7340 / PCI-7344 Motion Controller Card, 186307C-04 National Instruments NI PCI-7340 / PCI-7344 Motion Controller Card, 186307C-04 $500. . fr>: >Hello, >I've got a PCI card (PCI 7344 for motion control). The PXI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space. hwdb hwdb/20-pci-vendor-model. If you have non-plug and play (ISA bus) boards, refer to the ISA Installation (PC-FlexMotion-6C Only) section of this document. On the other hand please take into account that the PID loop is running much faster and in order to align the trajectory generation rate ( = 10 ms in contoured mode) and the PID rate (= up to 62,5 µs) the DSP. 579 views 3 years ago. Using PCI-7344 and MID-7604 and FLEXMOTION. Current PC config is: Pentium 4 - 2. 1 Release Notes 4 ni. In my program, the 1st step is to run "Clear Power Up Status. 4. For my research purpose I need some important information from you. I encountered problems controlling the motor with MAX using a digital signal. Any combination of 0 to 4 open loop or closed loop stepper motors and 0 to 4 servo motors (always closed loop) is allowed. PXI-7344 PXI/CompactPCI PCI-7344 PCI FW-7344* IEEE-1394 * Windows 2000/Me/98 only. I'm testing angle sensors whose voltage output is proportional to (you've guessed it. The first two axis (#1 and #2) both work fine. Overview of the 1-D Interactive Panel. de * Technical Support for Motion SoftwareI'm not sure what you mean by voice coil, but the UMI 7764 is designed to interface with third party amplifiers to drive motors. 10: Sơ đồ khối điều khiển máy Trong khuôn khổ đề tài, bộ điều khiển phay máy CNC 3 trục được xây dựng trên nền một máy PC gắn thêm mạch điều khiển chuyển động PCI-7344 của National Instruments Corp. There are no. Knight of NI. Hi, I updated my PCI-7344 + LabView 7. But the MAX couldn't read the current traject. The 7344 controllers are warranted against defects in materials and workmanship for a period of 1 year from the date of shipment, as evidenced by receipts or other documentation. I am currently working on a project related to nanomotion stage control using PCI-7344 and LabVIEW 6. Applications Engineering Group. 20. Restart and reinstall the drivers for NI-Motion - this will also add MAX. Last updated on Aug 11, 2023 10:17:38 PDT View all revisions View all revisions. Knight of NI. A National Instruments PCI-7344 4-axis controller card that resides in a PCI slot in a Windows PC controls motion. After this software upgrade, several things changed. Now i am using a PCI-7344 motion controller to control my nanomotion stage. Under windows system I use the flexmotion32. 1 . Axis 1 is working fine, i can control perfectly the motor, I. Depending on the movement of a xy - stage (controlled by the motion controller) I'd like to trigger a laser pulse. Options. Ca hai ho tr ay u viec lap trnh ieu khien chuyen ong cho phep ieu khien toi a 4 truc ong thi va oc lap. While this is happening, I need to change the velocity of one of the motors. 4-Axis, Stepper/Servo Motion Controller DeviceI'm using onboard (PCI-7344) Labview programming Wait On High Speed Capture (Wait On Condition. Manufacturer: National Instruments FW-7344, 4 Axes, 9 to 25 VDC, Stepper/Servo Motion Controller National Instruments FW-7344 Stepper/Servo Motion Controller The FW-7344 (Part Numbers: 186839C-01, 778113-01) is a Stepper/Servo Motion Controller. nce-file would it be possible to do the same thing with a C Series Motor Interface Module that uses the SoftMotion driver such as the NI 9514?PCI-7334 PCI-7344 Software. It is connected to a UMI-7764 breakout box. 0 Kudos Message 2 of 2. So, am I missing something ?, All the motors are 3rd Party. 14 PC-Based System with FP 2000 Hardware Configurations 42. 3-Axis control, stepper motors, closed loop with optical linear encoders. The reason for the 64-bit operation is a 3rd party function generator card that requires 64-bit LabView to work in conjunction with the 64-bit drivers. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. [systemd-commits] hwdb/20-OUI. Send. I am planning to use PCI-7344 to implement speed control for 7,5 kW induction motor. 01-30-2006 10:29 AM. I am trying to figure out the best way to calibrate encoders with the PCI-7344 interface card. It is very likely that you will not be able to simulate the FW-7344 controller in MAX, due to these limitations. g. The VIs send motion commands to the board and also monitor the position of the axis. Thanks, Hello Everyone, The Stepper Motors on My machine don't move on my machine, I have PCI -7344 card connected to UMI 7764 with 68 pin connector. And see the result. If I set the blend factor to 0 or larger values, the sharp corners reserve, but it seems that we h. It includes dual processors, a real-time onboard OS, and multiaxis interpolation. The cards do not work on a Computer with differen Hardware, nor when the operating system is Windows XP. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. NI-Motion Issue Details I can command my motion controller to move a stepper motor to a target position in Open Loop mode, but when I configure it to run in Closed Loop mode, the motor doesn't appear to complete the move, doesn't move at all,. 5500. Hi Im trying to connect an PCI version of the Ni7344 to a Compax C3 servo drive. 1, FLEX MOTION 5. The DISABLED LED of the Axis1 - Axis4 on the e UMI is not Lit, i also notice that in MAX under Motion IO setting, the "inhibit input setting" is grayed. . The PCI‑7344 also provides contouring capability for complex moves. 445 subscribers. The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. I´m develop an automated platform by means of stepper motors using the PCI 7344 board and the MID-7604. If I set the motor's. If you need a specific firmware or series relating to PCI-7344, we probably have it. Configure your stepper settings. PCI/PXI/FW Installation Complete the following steps to install your PCI/PXI/FW motion controller: 1. 4-Axis, Stepper/Servo Motion Controller Device Re: LabVIEWアップデートに伴うPCI-7344のエラー. 問題: 我嘗試要重設位置,但是總是不會歸零。 我的位置總是會被重設到零以外的數值,我該如何將它變為零. Mark as New;. Shut down your computer. 8 Ghz, 4 Gb Ram, Matrox Pahelia Video card (agp), PCI-7344 and FW-7344 (Firmware version 6. It's very dangerous,my compents are allways hit. 4-Axis, Stepper PXI Motion Controller Module. Hi, I am running a motor using the PCI 7344 motion control board and a MID-7654 servo with encoder feedback. sooner or later hardware will be discontinued, OS end of life, LabVIEW version not supported, etc. Using LV 7. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. No worries Chris. g. Regards, Shut down the system and physically remove the PCI-7344 from the system (important to remove resource locks). What does mean "Trigger Input occurred" and what kind of misconfiguration can cause it? Tanks. BUT, i though that the pci-7344, and the umi-7774 that i have should handle ALL the operations i need to drive the servo. . At Lektronix we can provide you with a brand new National Instruments PCI-7344 covered by the Original Manufacturers Warranty. Hardware Using the existing Rhino Robotics Ltd. The Problem is feedback from each axis (AZ & EL). I have 3 ORIEL motors (Model: 18277, 18215) to drive an x-y-z station. (NI). STL file there are 28 layers/faces. The 7344 can do a frequency of 40 Hz or 78 Hz (which either may or may. So i am just wondering if the SCB-68 can be used as the ter. 0. 17) before running VI. I checked the files that the person shared with me which are NI-Motion configurations. The secret is getting the correct Parker-Compumotor Gemini cable that plugs into the. Any combination of 0 to 4 open loop or closed loop stepper motors and 0 to 4 servo motors (always closed loop) is allowed. , Austin, Texas) installed in a supportive PC station are integrated using a LabVIEW software package (National Instruments Co. There does not appear to be any built-in support for that device. FlexMotion 5. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or. Thanks in advance George . Sorry but I can't give you any further help. Servo motors expect a pulse every . all controllers in the 7344/7334 family. Shut down the system and physically remove the PCI-7344 from the system (important to remove resource locks). Bgrain, there is no way to tweak a PCI-7344. If you select the Firmware tab, there should be a button near the top of the screen callled "Update Firmware" If the firmware is up to date, it will be grayed out. FlexMotion 5. 打开测量与自动化浏览器 (MAX) 导航到您的 NI Motion 设备. As the control loop is typically running much slower on the FP system compared to the PCI-7344, you will have to modify the PID parameters accordingly. we are using PCI 7344 and labview 7. The 7344 family of controllers includes the following controllers: • PCI-7344 • PXI-7344 • FW-7344 The 7344 controllers are high-performance controllers for PCI, PXI. 4-Axis, Stepper/Servo PXI Motion Controller Module—The PXI‑7344 is recommended for both simple and complex motion applications. I am having some trouble indexing an axis on our PCI-7344 card. The PCI-7334 is the NI low-cost stepper-only motion controller, which offers the flexibility and ease-of-use features found throughout the FlexMotion line of controllers. SoftMotion is a great alleviation as you can. We have just recently switched to a new hardware revision and now all boards don't show up with their specific names but with the name of the board family: Board Family Specific Boards. The fact is ,as most say,the driver is not suitable under non-windows systems. 00 shipping And i want to connect it to UMI-7774 with PCI-7344 also configured in MAX to work in P-Command mode. Member ‎05-26-2007 07:09 AM - edited ‎05-26-2007 07:09 AM. Go to the Axis Configuration option, under the desired axis (e. I have tried all the Settings discussed in the Forums and they still don't run. the PCI-7344 can control up to four axes. start using the board! The best place to see that is the readme files, and I see that for your board (7344), the correct version would be 5. (67 pages) Controller National Instruments sbRIO-9607 User Manual. Use a lower resolution stepper motor. Re: Position Control of compumotor linear servo table and GV-U6E with PCI-7344. JB. また、NIのホームパージから. rules. dll well with vc,but when I use it under rtx ,it does not work,appering " can not load the driver". This warranty includes parts and. The PCI-7342 supports buffered contouring mode. The onboard CPU uses an embedded real-time OS. This is one of true pains of maintaining legacy systems. 25 ms corresponding to 0 degrees, 1. 6 and LVRT 8. sooner or later hardware will be discontinued, OS end of life, LabVIEW version not supported, etc. If you are upgrading from a previousNI Product Documentation Center. Does anyone by chance has this card running on WIN10 daqmx? Thanks for Your help. 8 degree pitch (200 steps per rev). . 1 . The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. sawant@gmail. All the best-John 05-14-2002 08:10 AM. This warranty includes parts and labor. 579 views 3 years ago. Axis 1) In the Axis Configuration tab, set Type to Stepper. vi" to configure the digital port of my E-series DAQ (PCI-6052E), my motion controller's encoder stops working (PCI-7344). With LabView 7 motion control and the PCI-7344 cart I would like control two EC-Servomotors in combination with the Encoder HEDL 9140 and the ServoOther Devices as PCI Device. return to the previous setup which has NI-Motion 6. 09-27-2002 08:03 AM. Im not very advanced with Lab. lexmotion PCI-7344 with LabView for use as a Parabolic Antenna controller. PCI-7390 Driver. 4-Axis, Stepper/Servo Motion Controller Device4-Axis, Stepper/Servo PXI Motion Controller Module —The PXI‑7344 is recommended for both simple and complex motion applications. Maybe adaptive algorithm, or some other algorithm which I invented. can we get the VI for oscillator with variable frequency from 10 khz to 1 Mhz with variable duty cycle. This is a troubleshooting challenge. I have just completed the cable that connects the amplifier to the encoder. pci_fd The integer returned from the open() function. 40. . いつもお世話になっております。 現在,MAX上でモータのチューニングを行っているのですが,以下の4点について教えてください。 (motionボードはPCI-7344,UMIはUMI-7764を用いています) 1,Axis ConfigurationでTypeをServoとした場合に, どのような信号でモータの回転方向(正回転,逆回転)および速度. T. Now I have used to VI PWm duty and config PWM. Servo motors expect a pulse every . また、NIのホームパージから. It is built using off-the-shelf components (Galil servo motors, PWM power amplifiers with torque-control mode, Lintech manipulator, standard camera). The intent is to collect data at each grid point of an X-Y grid. Yes I am using a PCI-7344 controller. But when it comes to the analog output from UMI7774, i can't measure any signal from there while i am sending commands from. Support Worldwide Technical Support and Product Information ni. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. Lai Wechat:17750010683 Whats app:+86 17750010683The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. Features The 7344 controllers are a combination of servo and stepper motor controllers for PCI, PXI, and 1394 bus computers. Tie rod must be vibrated by linear servo hydraulic. Trusted Enthusiast. 32. The fact is ,as most say,the driver is not suitable under non-windows systems. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. If you are installing a PCI or PXI controller, install the controller in an available slot in your computer. Running the motor is not a problem but when it has stopped (there is no load) the servo system still puts out a lot of voltage (+-48V) all the time. So I wonder if there is driver u. Provides support for NI data acquisition and signal conditioning devices. For my research purpose I need some important information from you. How do I do that? Hopefully, there is also a way for me to h. Unless otherwise noted, text applies to all controllers in the 7344 family. Does this give you any clues? So you are saying this is a bug which was fixed with a patch in earlier LV versions? I didn't find any documentation on this. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming. National Instruments PXI-7344 Stepper/Servo Motion Controller Module. The 10 ms timing for contoured move is the fastest that you can get out of the board. (NI). basset@univ-valenciennes. Hope this helps, Jorge M. 3003. The marking triggering signal (TTL) generated by a rotary encoder is applied to the trigger input of the NI-MID 7604 module trough a delay circuit (2) and a logic gate (AND) of SPUC. 1) When I am stationary and command a Halt, there is a resulting jerk movement, sometimes up to a few 1000 servo steps. I encountered problems controlling the motor with MAX using a digital signal. Go to the Axis Configuration option, under the desired axis (e. 2. 0. Re: PCI-7344 motor interfacing help. The fourth axis should also operate in contouring mode. Is it possible to use the PCI-7344 board. The FW-7344 is only compatible with LabVIEW versions earlier than LabVIEW 8. These devices run the PID loop onboard in realtime and you only need to set parameters like travel distance, speed and acceleration. Hi all, I'm using the PCI-7344 board and I'd like to trigger an external device. 02 seconds. The 7334 controllersHello, We are planning to build a tie rod fatigue test system with Labview and NI PCI-7344 4-Axis Motion Control Board. Chapter 5 Signal Connections Analog Inputs The 7344/7334 controller has the following ADC input signals: • 7344/7334 Hardware User Manual Analog Input <1. When calling "DIO Port Config. Each axis uses 2 Synchro's (1:1 & 36:1 for Course & Fine 90V / 60Hz) for feedback. I have no choice in using synchro's as feedback. Axis 1) In the Axis Configuration tab, set Type to Stepper. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. . My requirement is 1 Khz samples . Author. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Conventions The following conventions appear in. i finally start to understand the setting after i read the PCI7390 which is position-comannd controller. Conventions National Instruments PCI-7344 Motion Controller Device. The 7344 controllers are a combination of servo and stepper motor controllers for PCI, PXI, and 1394 bus computers. I would like to implement control algorithm on PCI 7344 (Don't want to use the built-in PID). Hello, we are running our lab setup on WIN7 and soon we have to switch to WIN10. As the control loop is typically running much slower on the FP system compared to the PCI-7344, you will have to modify the PID parameters accordingly. com FlexMotion Software Installation Install the FlexMotion software before installing a FlexMotion series motion controller for the first time. Hi, I use PCI-7344 and UMI-7764 and upgrade the motion software and firmware to 7. In MAX under NI-Motion select your PCI-7344. controller in the 7344 family and contains information concerning their operation and programming. I am able to get a nice response c. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. 10-02-2007 06:58 AM. The Payment Card Industry (PCI) Data Security Standards (DSS) is a global information security standard designed to prevent fraud through increased control of. Letter of Volatility. I have verified the connection is working. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. 2的强大功能,我们得以 在短时间内完成了控制系统的开发,同 时保证了机械臂的运动精度与负载能 力。The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. Hello, After having configured mu board PCI-7344 under MAX software (1axis activated because 1 only axis used, standard of stepper in open Loop. Please refer to the contouring examples shipping with LabVIEW. National Instruments PCI-7344 Motion Controller Device. National Instruments PCI-7314 Driver Download (Official) The PCI-7314 is a device manufactured by National Instruments. We used NI vision (IMAQ PCI-1409), motion controller (PCI-7344), and DAQ (PCI-6025E) cards for this MPVIEW. 11-09-2010 03:33 PM. The 3 axes operate together in contouring mode. The Hardware limits work as expected. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. Also try to update firmware, by updating the ni-motion driver, and then go to MAX and click PCI-7344, and then in the right window click the firmware tab, and then click update firmware. I am using LabVIEW 2014 and NI PCI 7344(motion controller). 1. 3. The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. 2 version but I can't be initialize the motion card in MAXDiscontinued NI motion products (PCI/PXI-7334) Affected model numbers include: PCI-7332; PCI-7334; PCI-7342; PCI-7344; PCI-7352; PCI-7354; PCI-7356; PCI-7358Issue Details I have a PCI-7344 with a UMI-7774 and a Yaskawa Servo Motor and Driver. hwdb Marcel Holtmann holtmann at kemper. How can. Mark as New; Bookmark. e. . In this Pin No 5 and Pin No9 are PWM1 and PWM2 respectively. 32. The event never seems to fire. MAX 5. On 2 different systems and 2 different motion control cards (pci-7334 and 7344) after running the cards for approximately 30 minutes I get errorThe PCi 7344 can control a brushless servo provided that the drove for your motor can take a +/- 10 volt torque signal or a step and direction signal as a command signal. Options. comPXI-7344. 我使用的硬件是PCI-7344,UMI-7764,Sanyo 伺服驱动器和伺服马达一套 运动控制卡的驱动是NI-Motion7. It offers linear interpolation for coordinating multiple axes, real-time system integration for directly communicating with data acquisition or image acquisition hardware, and high. This warranty includes parts and labor. If it's possible to update your application to LabVIEW 2015+, my company has a replacement solution for PCI-7344. Re: problems with a PCI-7344 motion controller. 0 Kudos Message 1 of 2 (1,817 Views)Lực cắt tham chiếu CNC FANUC Máy tính 2 + Phần mềm hiển thi (DASYLab)+ Điều khiển thích nghi Q trình phay Lượng chạy dao Card điều khiển Flexmotion PCI - 7344 Máy tính 1 + CNC Controller Card PCL -812PG Điều chỉnh lượng chạy dao Luợng chạy dao Lực kế Hình 1. There was a "broken" device PCI-7344 under NI Motion Devices, which status said something like "This device has been removed or could not be detected" and the Res. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help.